RELATED-LINK-collettori
sistemi_contabiliz-vantaggi_moduli e satelliti utenza_stacchi

GE555 USER MODULES


GE555 is a family of user modules for the direct metering of heating and cooling energy consumption, as well as that of hot and cold sanitary water in the installations with central production and zone distribution systems.

The units can be used both for heating and conditioning, thanks to the heat energy meter with double register that complies with the MID Directive (2004/22/EC) and arranged for communication according to the M-Bus standard. Optionally, also the consumption of hot and cold sanitary water can be measured, by adding GE550 units or pre-assembled groups.


 


 

GE555 STANDARD MODULES
This is the classic solution for installations with centralized production and zone distribution, as it allows the ON-OFF control of the heating and cooling system and the direct measurement of the energy used for heating and cooling. Optionally it is also possible to measure the volumes of sanitary water (cold and hot) and service water, the latter requirement arises from the diffusion of dual networks, where the water is distributed with different circuits depending on the end use.

 


 

GE555 USER MODULES WITH DISTRIBUTION MANIFOLDS
The user modules are also available with the predisposition for the installation of distribution manifolds inside the box. This solution is particularly suitable for residential buildings with small apartments, because it saves the space normally required for the installation of distribution manifolds inside the flat.

 


 

GE555 MULTIUSER MODULES
If the available space is limited, even in the common areas of the building, the multi-user modules represent a compact and rational solution. The consumption of several apartments is measured individually, but they are served by a single module. The product range offers maximum flexibility, since are available pre-mounted groups in boxes, as well as separate components for the construction of modules tailored to the needs of the individual installation or building.

 

 


 

GE555 MODULES WITH HYDRAULIC SEPARATOR
The user modules with integrated hydraulic separator allow complete hydraulic separation between primary and secondary flows, and for this reason, they are the ideal solution when in the same apartment there is a mixed installation. That is the increasingly common case of installations with a radiant floor or a radiant ceiling system used not only for heating, but also for room cooling. The terminal units for the removal of humidity make it necessary to provide fluids at two different temperatures.

 

 


 

GE555 USER MODULES FOR R586P UNIVERSAL BOILER GROUPS
These special user modules have been developed specifically for use in combination with the R586P universal groups for boilers. They allow the measuring of the consumption for heating and cooling and, optionally, for sanitary water. R586P groups are used in heating or cooling systems where are required fluids at different temperatures and, in particular, where there are radiant floors or ceilings. For this purpose they have both a direct connection and a mixed connection.