Pinch-point heat recuperators (decentralized HRV)

KVP-T Additional electronic card for temporized operation of KVP units

KVP-T Additional electronic card for temporized operation of KVP units

Additional electronic card for KVP spot extraction fan. For temporized operation.

TIMER: It starts the aspirator when the light or dedicated switch is turned on and to keep it running when off, for a time included between 45 seconds and 20 minutes, programmable through an internal trimmer.

TIMER WITH HUMIDISTAT: It starts the aspirator when the level of relative humidity inside the room exceeds the activation set point and keeps it running till the humidity level doesn’t go below such threshold.
When reaching the set point, the timing function enables the aspirator to keep running for a time programmable between 45 seconds and 20 minutes so as to further reduce the relative humidity inside the room.
The relative humidity threshold can be set between 40-80%.
Aspirator for manual use also available with TIMER function.

Products

Code Size BIM(revit) CAD(dxf) Certification
KVPTY001 Timer 1 0 - -
KVPTY002 Timer 1 0 - -

Do you need help with KVP-T?

If you need further information concerning any product, please get in touch with our local Staff

Find your Giacomini consultant

Related products