Modular heat interface units (HIU) for thermal energy consumptions in heating systems and hot domestic water production in modern autonomous systems with centralized heat production.
Possibility to assemble various components to create an interface unit suitable based on installation needs (control of high/low temperature heating with/without balancing valves, control of domestic hot/cold water, etc.).
- Max. working temperature of primary and secondary circuits (heating and hot domestic water): 90 °C
- Max. working pressure of primary and heating secondary circuits: 10 bar
- Max. differential pressure of primary circuit: 0,5 bar (0,5÷2 bar if present GE556Y532)
- Max. working pressure of hot domestic water circuit: 10 bar
- Temperature range of heating secondary circuit: 20÷70 °C (Set-point 45 °C)
- Temperature range of hot domestic water secondary circuit: 20÷70 °C (Set-point 50 °C)


----------------------------------------------------------------


MODULAR HEAT INTERFACE UNIT: SM3 VERSION
Starting from the GE556Y505/506 basic codes, the heat interface unit can be configured with additional product codes and possible optional.

- Basic codes
•GE556Y505: Lower primary connections
•GE556Y506: Upper primary connections

- Hot domestic water circuit - Heat exchangers
•GE556Y511: 16-plate exchanger + 5 mm insulation
•GE556Y512: 16-plate exchanger + 20 mm insulation
•GE556Y513: 26-plate exchanger + 5 mm insulation
•GE556Y514: 26-plate exchanger + 20 mm insulation
•GE556Y515: 36-plate exchanger + 5 mm insulation
•GE556Y516: 36-plate exchanger + 20 mm insulation

-Hot domestic water circuit - Control components
•GE556Y521: HDW production with no controls
•GE556Y522: HDW production with thermostatic control

- Primary circuit
•GE556Y531: Primary circuit connections with no controls
•GE556Y532: Primary circuit connections with differential pressure control valve with double setting
•GE556Y530: Primary circuit connections with compact differential pressure control valve

- Secondary circuit
•GE556Y549: Secondary circuit, direct heating with no controls
•GE556Y548: Secondary circuit, direct heating with static balancing
•GE556Y549: Secondary circuit, direct heating with presetting valve, possible installation of thermo-electric actuator
•GE556Y540: Secondary circuit, low temperature heating kit (pump + thermostatic head).

- Optional
•GE556Y551: Insulation
•GE556Y561: Cold domestic water outlet unit output
•GE556Y567: Domestic water recirculation unit output with pump
•GE556Y568: Domestic water recirculation unit output without pump
•GE556Y566: Thermostatic by-pass to maintain constant the hot domestic water temperature of the heat exchanger
•GE556Y569: Drain cocks

- Completion codes
•GE551Y089: Template with 6 shut-off valves, for GE556Y505 or GE556Y506 HIU including insulation
•GE551Y090: Lowered template with 6 shut-off valves, for GE556Y505 or GE556Y506 HIU without insulation
•GE500Y255: Additional cold domestic water valve, for installation on template with GE556Y561 optional kit
•GE500Y261: Pair of additional valves for low temperature heating supply and return, for installation on template with GE556Y540 kit for secondary circuit
•GE551Y185: Metal cover for HIU, only for HIU with GE551Y089 template
•R473/R473M: Thermo-electric actuator normally closed to control presetting valve, included with GE556Y543 kit (R473X221 230 V; R473X222 24 V; R473MX221 230 V; R473MX222 24 V)
•GE552: Thermal energy meter (GE552Y159 3/4”, volumetric, 1,5 m3/h, M-Bus; GE552Y216 3/4”, volumetric, 1,5 m3/h, M-Bus
with Wireless M-Bus predisposition; GE552Y122 3/4”, ultrasounds, 1,5 m3/h, M-Bus)
•GE552-2: Domestic water meter (GE552Y191 3/4”, hot domestic water;GE552Y190 3/4”, cold domestic water, to be ordered separately if GE556Y561 additional unit output is present)


----------------------------------------------------------------


MODULAR HEAT INTERFACE UNIT: COMPACT VERSION
Starting from the GE556Y503/504 basic codes, the heat interface unit can be configured with additional product codes and possible optional.

- Basic codes
•GE556Y503: Lower primary connections
•GE556Y504: Upper primary connections

- Hot domestic water circuit - Heat exchangers
•GE556Y511: 16-plate exchanger + 5 mm insulation
•GE556Y512: 16-plate exchanger + 20 mm insulation
•GE556Y513: 26-plate exchanger + 5 mm insulation
•GE556Y514: 26-plate exchanger + 20 mm insulation
•GE556Y515: 36-plate exchanger + 5 mm insulation
•GE556Y516: 36-plate exchanger + 20mm insulation

- Hot domestic water circuit - Control components
•GE556Y521: HDW production with no controls
•GE556Y522: HDW production with thermostatic control

- Primary circuit
•GE556Y531: Primary circuit connections with no controls
•GE556Y532: Primary circuit connections with differential pressure control valve with double setting
•GE556Y530: Primary circuit connections with compact differential pressure control valve

- Secondary circuit
•GE556Y544: Secondary circuit, direct heating with presetting valve, possible installation of thermo-electric actuator

- Optional
•GE556Y552: Insulation
•GE556Y561: Cold domestic water outlet unit output
•GE556Y564: Domestic water recirculation unit output with pump
•GE556Y565: Domestic water recirculation unit output without pump
•GE556Y566: Thermostatic by-pass to maintain constant the hot domestic water temperature of the heat exchanger
•GE556Y569: Drain cocks

- Completion codes
•GE551Y087: Template with 6 shut-off valves, for GE556Y503 or GE556Y504 HIU including insulation
•GE551Y088: Lowered template with 6 shut-off valves, for GE556Y503 or GE556Y504 HIU without insulation
•GE500Y258: Additional cold domestic water valve, ,,for installation on template with GE556Y561 optional kit
•GE551Y184: Metal cover for HIU, only for HIU with GE551Y087 template
•R473/R473M:Thermo-electric actuator normally closed to control presetting valve, included with GE556Y543 kit (R473X221 230 V; R473X22224 V;R473MX221 230 V; R473MX222 24 V)
•GE552: Thermal energy meter (GE552Y159 3/4”, volumetric, 1,5 m3/h, M-Bus; GE552Y216 3/4”, volumetric,1,5 m3/h, M-Bus
with Wireless M-Bus predisposition; GE552Y122 3/4”, ultrasounds, 1,5 m3/h, M-Bus)
•GE552-2: Domestic water meter (GE552Y191 3/4”, hot domestic water; GE552Y190 3/4”, cold domestic water, to be ordered separately if GE556Y561 additional unit output is present)

Info

IMPORTANT
Second to last number of each product code indicates product type:
0 for heat interface unit base
1 for heat exchanger of domestic water circuit
2 for control components of domestic water circuit
3 for control components of primary circuit
4 for control components of secondary circuit (heating)
5 for insulation (optional)
6 for other optional components

To ensure proper operation of heat interface unit, order at least one product code for each type of component with 0, 1, 2, 3, 4 as second to last figure.

Product codes with 5, 6 as second to last figures are considered optional.

Do you need help with GE556-5?

If you need further information concerning any product, please get in touch with our local Staff

Find your Giacomini consultant

Related products