Pinch-point energy recovery units - decentralized HRV

KVP-T Additional electronic board for temporized operation of KVP units

KVP-T Additional electronic board for temporized operation of KVP units

Additional electronic board for KVP spot extraction fan. For temporized operation.

TIMER: It starts the vacuum unit when the light or dedicated switch is turned on and it keeps it activated when they are turned off for a time programmable between 45 seconds and 20 minutes, programmable through an internal trimmer.

TIMER WITH HUMIDISTAT: It starts the vacuum unit when the level of relative humidity inside the room exceeds the activation set point and keeps it running till the humidity level, drops below such threshold.
When reaching the set point, the timing function enables the vacuum unit to keep running for a time programmable between 45 seconds and 20 minutes so as to further reduce the relative humidity inside the room.
The relative humidity threshold can be set between 40-80%.
Manual vacuum unit available also with TIMER mode.