Hydronic unit for heat pumps, designed for optimal control of heating/cooling services and hot domestic water (HDW).
- Metal frame for wall fitting.
- Preassembled solution to cut down the time required for installation and prevent execution errors.
- Connection to HDW storage.
- Control of thermal storage tank to decouple the heating/ cooling system from the heat pump status: HDW production during cooling or execution of defrosting cycle during heating.
- Diverting valve to change over the control modes of both the HDW storage and the heating/cooling services.
- Magnetic dirt separator with high filtering capacity.
- The unit can be completed with a relaunching pump, an insulation (for codes without insulation) and a diverting valve actuator.
R586HPIY005, R586HPIY015: with 40-sec. diverting valve (R279D)
R586HPIY105, R586HPIY115: with 8-sec. diverting valve (R279B)
COMPLETION CODES FOR R586HPIY005
- K270Y101: actuator 230 V, for 40-sec diverting valve (R279D)
- K270Y102: actuator 24 V, for 40-sec diverting valve (R279D)
- R540FY002: contact thermometer, red color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- R540FY022: contact thermometer, blue color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- R586HPIW005: insulation
- P76WHPIY001: Wilo Para 25/7 pump kit, center distance 130 mm, with ball valve and check valve
- P76WHPIY002: Wilo Para 25/7 pump kit, center distance 180 mm, with ball valve and check valve
- R197HPIY001: spacer kit for pump installation, center distance 130 mm, with ball valve and check valve
- R197HPIY002 spacer kit for pump installation, center distance 180 mm, with ball valve and check valve
COMPLETION CODES FOR R586HPIY105
- K270Y211: actuator 230 V, for 8-sec diverting valve
- R540FY002: contact thermometer, red color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- R540FY022: contact thermometer, blue color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- R586HPIW105: insulation
- P76WHPIY001: Wilo Para 25/7 pump kit, center distance 130 mm, with ball valve and check valve
- P76WHPIY002: Wilo Para 25/7 pump kit, center distance 180 mm, with ball valve and check valve
- R197HPIY001: spacer kit for pump installation, center distance 130 mm, with ball valve and check valve
- R197HPIY002 spacer kit for pump installation, center distance 180 mm, with ball valve and check valve
COMPLETION CODES FOR R586HPIY015
- K270Y101: actuator 230 V, for 40-sec diverting valve (R279D)
- K270Y102: actuator 24 V, for 40-sec diverting valve (R279D)
- R540FY002: contact thermometer, red color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- R540FY022: contact thermometer, blue color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- P76WHPIY001: Wilo Para 25/7 pump kit, center distance 130 mm, with ball valve and check valve
- P76WHPIY002: Wilo Para 25/7 pump kit, center distance 180 mm, with ball valve and check valve
- R197HPIY001: spacer kit for pump installation, center distance 130 mm, with ball valve and check valve
- R197HPIY002 spacer kit for pump installation, center distance 180 mm, with ball valve and check valve
COMPLETION CODES FOR R586HPIY115
- K270Y211: actuator 230 V, for 8-sec diverting valve
- R540FY002: contact thermometer, red color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- R540FY022: contact thermometer, blue color, scale 0÷120 °C, Ø40 mm (to be installed on the T-handles of the ball valves instead of the colored plates)
- P76WHPIY001: Wilo Para 25/7 pump kit, center distance 130 mm, with ball valve and check valve
- P76WHPIY002: Wilo Para 25/7 pump kit, center distance 180 mm, with ball valve and check valve
- R197HPIY001: spacer kit for pump installation, center distance 130 mm, with ball valve and check valve
- R197HPIY002 spacer kit for pump installation, center distance 180 mm, with ball valve and check valve
Code | Size | BIM(revit) | CAD(dxf) | Certification | ||
---|---|---|---|---|---|---|
R586HPIY005 | G 1”F /diverting valve 40 s | 1 | 0 | - | - | |
R586HPIY105 | G 1”F /diverting valve 8 s | 1 | 0 | - | - |
Code | Size | BIM(revit) | CAD(dxf) | Certification | ||
---|---|---|---|---|---|---|
R586HPIY015 | G 1”F /diverting valve 40 s | 1 | 0 | - | - | |
R586HPIY115 | G 1”F /diverting valve 8 s | 1 | 0 | - | - |